Structural strengthening of corroded reinforced concrete slabs

To restore the load-bearing capacity of a parking garage slab affected by severe steel corrosion, solidian GRID was applied as an approved supplementary reinforcement solution in combination with cathodic corrosion protection, without closing the lower parking levels.

Project background

The parking garage Dammstraße in Ludwigshafen showed significant corrosion damage in the upper layer of steel reinforcement. Chloride-contaminated concrete had led to a reduction in load-bearing capacity and required structural strengthening of the slab.

A complete replacement of the slab would have resulted in the closure of the parking levels below and significant operational downtime. Therefore, an alternative strengthening solution had to be implemented while keeping the structure in service.

Technical challenge

  • Severe corrosion in the upper steel reinforcement layer
  • Chloride-contaminated concrete cover
  • Lower reinforcement layer remained intact and load-bearing
  • Full replacement would have required shutting down several parking levels
  • Structural strengthening had to be verifiable according to the new guideline

Solution

For the first time, approved solidian GRID reinforcement was applied as a supplementary reinforcement and statically accounted for according to the new regulation.

After removing the damaged upper concrete layer, a new concrete overlay was applied, reinforced with solidian GRID as a replacement for the removed reinforcement layer. In addition, a cathodic corrosion protection system (CCP) with titanium mixed-oxide mesh anodes was installed to secure the remaining load-bearing capacity of the existing steel reinforcement.

The compatibility of the carbon reinforcement with the cathodic corrosion protection system was verified – no interference between the systems was detected.

Project partners:

Q-Park Operations Germany GmbH & Co. KG
Ed. Züblin AG – Direktion Bauwerkserhaltung

Project data

Location Ludwigshafen, Germany
Structure Parking garage slab
Application Structural strengthening / restoration
Products used solidian GRID carbon
Additional system Cathodic corrosion protection (titanium MMO mesh anodes)
Project partners Q-Park Operations Germany GmbH & Co. KG
Züblin AG – Direktion Bauwerkserhaltung

Structural strengthening without shutdown

Key benefits

  • Structural strengthening without closing the parking levels below
  • Preservation of the existing structure and lower reinforcement layer
  • Approved carbon reinforcement solution according to new guideline
  • Combination of strengthening and long-term corrosion protection
  • Reduced downtime and lower intervention compared to full replacement

Additional execution details

  • Substrate preparation: 2300 m² with mechanical interlock joints
  • Fixing of 1–2 layers Q95-CCE-38 with spacers and uplift protection
  • Concrete quality: C30/37 according to DIN EN 206
  • Carbon reinforcement placed directly over Styrodur mats