Primafloor

Reinforce screed for effective crack control
solidian Primafloor will minimize cracks during the most critical time of drying and curing of bonded screed, floating screed, unbonded screed or underfloor heating screed.

This flexible solution makes installation easier while ensuring strong durability and protection, offering long-lasting reliability in any environment.

  • Controls screed cracks during 28 days of drying and curing
  • Flexible reinforcement with superior adhesion
  • Easy installation and manipulation
  • Perfect for indoor and outdoor floors
  • Non-magnetic reinforcement - ensures safety in MRI environments by eliminating magnetic interference
  • Great tensile strength and impact resistance

Our Primafloor range is CE certified in accordance with EAD 260057-00-0303 and ETA 22/0296.

Product Features

Advantages
  • Made of glass, carbon, or basalt fibers, depending on the performance needed
  • Easy, fast and safe
  • Excellent mechanical properties
  • Non-corrosive and non-magnetic
  • Flexible reinforcement
  • In-house developed technique & technology
  • INDOOR and OUTDOOR usage

reinforcements for the future generations

CE mark
Flexibile
Easy Installation
No Electromagnetic
Corrosion Free
ARTICLES
Name Certificate Material Mesh size / opening (mm) Weight (g/m2) TDS/DOP
Primafloor 130 CE mark E/ECR-glass 40x40 130
Primafloor 145 CE mark E/ECR-glass 40x40 145
Primafloor 340 CE mark E/ECR-glass 14x14 340
Primafloor B215 CE mark Basalt 25x25 215
Primafloor C220 CE mark Carbon 18x18 220

Reference project

Product Applications

solidian Primafloor is used to control screed cracks during 28 days of drying and curing. Ideal for bonded screed, floating screed, unbonded screed or underfloor heating screed. Position of the mesh 1/2 or 2/3 of the screed thickness, overlapping 10cm.

Perfect for: indoor floor, outdoor floor, terrace, garage, garden, flat roofs, balcony, workshop, hall, office, gym...

1/3

We are here for you!
Send us your request and we will respond as soon as possible!

Invalid Input
Invalid Input
Invalid Input
Invalid Input. Please enter only numbers like this: 00385911234567
Invalid Input
Invalid Input
Invalid Input
Invalid Input

Contact Status

Invalid Input
Invalid Input

Product type

Invalid Input

Technology

Invalid Input
Invalid Input

Raw materials

Invalid Input
Invalid Input

Construction applications

Invalid Input
Invalid Input

Composite applications

Invalid Input
Invalid Input

Additional information

Invalid Input

Additional notes

Invalid Input

File upload

Invalid Input
Invalid Input

    frequently asked questions

    Your top inquiries, addressed
    • Performance Enhancement
    • Handling and Logistics
    • Compliance and Compatibility
    • Application and Installation
    • Durability and Resistance
    • Sustainability and Environmental Impact
    • Is solidian GRID suitable for replacing corroded steel reinforcement?
    • How does solidian GRID contribute to system durability when used with mortars?
    • Can solidian GRID conform to curved surfaces during installation?
    • How does the weight of solidian GRID affect transportation and installation?
    • Is there an Environmental Product Declaration available for solidian GRID and solidian REBAR?
    • Has solidian GRID received official building approvals?
    • With which types of binders is solidian GRID compatible?
    • Is solidian GRID approved for use in standard concrete applications?
    • What is the minimum thickness required for concrete layers using solidian GRID?
    • Can solidian GRID be used to reinforce existing concrete structures?
    • What is the expected lifespan of solidian GRID in wastewater applications?
    • How does solidian GRID perform in acidic environments?
    • How does solidian GRID contribute to sustainable construction?

    Yes, in cases where steel reinforcement has corroded, solidian GRID can serve as a substitute for structural reinforcement. The existing corroded steel can remain in place and be covered with a new layer of carbon-reinforced mortar, restoring structural integrity.

    When combined with high-quality mortars, solidian GRID significantly enhances the overall durability of the system, providing a robust solution for demanding environments.

    Yes, solidian GRID strikes a balance between stiffness and flexibility, allowing it to be applied to curved surfaces with diameters greater than 800mm.

    The lightweight nature of solidian GRID facilitates easy transportation, even through sewage tunnels, and simplifies the installation process, reducing labor and equipment requirements.

    Yes, a certified Environmental Product Declaration (EPD) is available for both solidian GRID and solidian REBAR. The EPD provides transparent and verified information about the environmental impact of these products throughout their life cycle, supporting sustainability assessments in construction projects.

     

    Yes, solidian GRID has obtained the General Building Approval (abZ) from the German Institute for Building Technology (DIBt). This approval authorizes its use as carbon reinforcement grids in construction, ensuring compliance with national building standards.

    solidian GRID is versatile and works with a range of binders, including Portland Cement, Calcium Aluminate Cements, and Geopolymer Cements.

    solidian GRID holds German Approval as reinforcement for EN 206 concretes, supporting its compatibility with various mortar systems, including those adhering to DIN 19573.

    Concrete layers reinforced with solidian GRID can be as thin as 20mm, as no additional concrete cover is needed to protect the reinforcement from corrosion.

    Yes, solidian GRID can be applied as an additional layer over existing steel-reinforced concrete. When combined with solidian ANTICRACK, it offers enhanced crack-limiting properties, providing extra protection to the underlying steel reinforcement.

    Classified under XWW4, solidian GRID ensures long-term performance for over 50 years, making it a durable choice for long-term infrastructure projects.

    solidian GRID is fully resistant to severe acidic conditions, including environments with pH levels as low as 0. It has successfully passed tests in accordance with DIN 19573 standards for pH 0 and pH 1.

    solidian GRID enables the design of thinner concrete layers (greater than 20mm) without requiring additional concrete cover for reinforcement protection. This reduction in material usage leads to lower resource consumption and a diminished environmental footprint, supporting more sustainable construction practices.

    Additional information:

    • Resource efficiency: By minimizing the need for extra concrete cover, solidian GRID conserves materials such as cement and aggregates, contributing to resource efficiency.
    • Environmental Product Declarations (EPDs): solidian provides transparent data on the environmental impact of their products through EPDs, facilitating informed decision-making for sustainable building projects.
      Solidian Kelteks
    • Reduced CO₂ emissions: The use of solidian GRID in construction can lead to significant reductions in CO₂ emissions due to decreased material usage and enhanced durability, which extends the lifespan of structures and reduces the need for repairs.